Skip to content

Telecom network and systems monitoring: from alarm to ticket

B2Bnetwork team · · 6 min

IT in telecom

In brief

Operator monitoring turns thousands of signals from the network and IT systems into a small number of tickets that someone fixes. The path leads from an alarm raised by a network element, through deduplication and correlation that identifies the root cause, through an assessment of the impact on services and customers, to a ticket with an owner and a deadline. What helps most is a shared alarm model (ITU-T X.733, TMF642), suppressing alarms during planned work and a service dependency map built from inventory.

The path from alarm to ticket

It is worth starting with terms, because many teams use them differently:

  • event: any piece of information from the network or a system, for example a load threshold being crossed;
  • alarm: an event that describes an abnormal condition and lasts until the condition clears;
  • incident: an outage or degradation of service felt by customers or business processes;
  • ticket: a task in the service management system, with an owner, a priority and a deadline.

A typical flow in a network operations center (NOC):

  1. A network element sends an alarm to the fault management system, for example over SNMP, a telemetry stream or a vendor interface.
  2. The fault management system normalizes the alarm into a common model and removes repeats.
  3. Correlation links alarms with a single cause and points to the one that describes it.
  4. Impact assessment determines which services and customers are affected.
  5. A rule or the on-duty engineer creates a ticket (TMF621 Trouble Ticket in the TM Forum standard) and assigns it to a team.
  6. After the fix the alarm clears, and the ticket is closed with a description of the cause.

The event streams this path relies on are covered in the article on real-time network events.

The alarm model: what it must contain

Alarms from different vendors look different, so the first step is a common model. The foundation is ITU-T Recommendation X.733 (Alarm reporting function). Among other things it defines alarm types (communications, quality of service, processing error, equipment, environmental), the probable cause and the perceived severity: critical, major, minor, warning, indeterminate and cleared.

The TMF642 interface (Alarm Management) carries this model into REST and adds fields that are useful in practice:

TMF642 fieldWhat it is for
`alarmedObject`which element or service reports the problem
`perceivedSeverity`severity consistent with X.733
`probableCause`, `specificProblem`cause according to X.733 and the vendor's description
`isRootCause`, `correlatedAlarm`, `parentAlarm`the correlation result: cause and effects
`serviceAffecting`whether the alarm affects a service
`plannedOutageIndicator`whether the alarm comes from planned work
`ackState`whether someone has acknowledged the alarm

TMF642 operations include acknowledging, clearing, commenting on and grouping alarms. With this model the ticketing system and dashboards do not need to know every vendor's format.

Correlation and noise reduction

The failure of a single backbone link can trigger hundreds of alarms: from the link itself, from the devices behind it, from services that stopped working and from IT systems that lost connectivity. An on-duty engineer who sees all of them sees nothing. That is why:

  • deduplication merges repeats of the same alarm into one with a counter;
  • topology correlation uses the network inventory: if a link is down, alarms from devices behind it are effects;
  • time correlation links alarms that appear together within a short window;
  • suppression during planned work marks alarms from elements covered by a maintenance window instead of creating tickets from them.

The same mechanisms apply to monitoring IT systems. Prometheus Alertmanager calls them grouping, inhibition (suppressing dependent alerts) and silences. Organizing maintenance windows is covered in the article on night work at an operator.

From alarm to impact on services and customers

An alarm says something is not working in the network. A ticket should say who is affected. For that you need a dependency map: which services use a given element and which customers have those services. The map is built from service and resource inventory, so monitoring quality depends directly on inventory quality.

Once the impact is known, you can:

  • set the priority by the number and type of customers, not just alarm severity;
  • inform customer care and the IVR, so callers hear about the outage before they report it themselves;
  • link customer tickets to a single technical problem instead of handling each one separately.

TM Forum describes service-level problems in a separate API, TMF656 (Service Problem Management). Integration with customer care is covered in the article on CRM, IVR and customer service automation. A major outage may also have to be reported to a supervisory authority, as we discuss in the piece on incident reporting under DORA and NIS2.

Monitoring the operator's IT systems

BSS, mediation, portals and customer apps break too, and customers cannot tell a network outage from an app outage. IT systems are monitored with metrics, logs and distributed traces. OpenTelemetry provides a common, vendor-neutral way to collect this data. More on this in the article on observability.

For IT systems, alerting on symptoms the customer sees works better than alerting on causes: the share of failed orders, portal response time, mediation lag. The targets and thresholds for such alerts are easier to set with the approach described in the article on SLOs and error budgets. In virtualized networks the network and IT run on the same platform, as in the scenario on a Kubernetes platform for network functions, so a shared alarm model becomes even more important.

Automation and testing of monitoring

Rules that create tickets automatically have to be tested like code, because a faulty rule either stays silent during an outage or buries the on-duty team. The test plan covers:

  • injecting alarms from a simulator and checking that exactly one ticket was created with the right priority and team;
  • an alarm storm: thousands of alarms in a short time, checking that correlation keeps up;
  • clearing: does an alarm cleared in the network close or update the ticket;
  • maintenance windows: are alarms from planned work suppressed, while alarms outside the window are not;
  • dependencies: after a topology change, is the service impact map still correct.

The best test is a regular drill with a real, controlled failure in a test environment or during a maintenance window.

Questions and answers

What is the difference between an alarm and an incident?

An alarm is technical information from a network element or system about an abnormal condition that lasts until it clears. An incident is an outage or degradation of service that customers or processes feel. One incident usually triggers many alarms, and some alarms mean no incident at all, for example when a redundant link takes over.

What is a NOC at a telecom operator?

A NOC (Network Operations Center) is the network monitoring center where on-duty engineers watch alarms around the clock, assess the impact of failures and pass tickets to repair teams. Many operators also run a SOC, a security operations center that deals with threats. Both rely on similar correlation mechanisms and should share information.

What alarm severity levels does ITU-T X.733 define?

Recommendation X.733 defines perceived severity as critical, major, minor, warning, indeterminate and the cleared state. TMF642 uses the same set. Alarm severity is not yet the ticket priority: the priority should also take into account the number of customers and services the problem affects.

How do you reduce the number of false alarms?

Through deduplication, topology correlation, suppression during planned work and regular rule reviews. Alerting on symptoms the customer sees rather than on every technical threshold also helps. Once a month it is worth reviewing the alarms that led to no action and, for the most frequent ones, changing the threshold or rule or switching them off.

What it looks like in a project

Changing an operator's systems? Talk to an engineer who has done it in night windows.

Let's talk

Read more: IT in telecom